Donnerstag, 12.10.2006,
CURAC Navigation 1 + Robotik 1
10.00–15.00
Hörsaal R
|
| 10.00 |
Begrüßung
T. Lenarz, H. K. Matthies (Hannover) |
|
| |
10.30–12.30
Navigation I
Vorsitz: G. Strauß (Leipzig), N.-C. Gellrich (Hannover) |
|
10.30
1 |
Quality assurance for 3D navigation
W. Freysinger, F. Kral, G. Diakov, Z. Güler, R. Stoffner (Innsbruck) |
 |
10.40
2 |
First results of accuracy of virtual liver cut classification for
automatic landmark extraction
S. Schlichting, V. Martens, N. Rzezovski, A. Schweikard, H.-P. Bruch (Lübeck) |
 |
10.50
3 |
First steps towards impartial intraoperative accuracy
assessment in computer aided surgery
C. Bohr, J. Wurm, D. Tim, H. Iro, K. Bumm (Erlangen) |
 |
11.00
4 |
Improving registration accuracy in medical augmented reality
J. Fischer, M. Eichler, J. Hoffmann, M. Tatagiba, W. Straßer, D. Bartz (Tübingen) |
 |
11.10
5 |
Stabilität verschiedener Referenzsternbefestigungen gegenüber
mechanischer Belastung
M. Citak, D. Kendoff, P. Bretin, V. Look, C. Krettek, T. Hüfner
(Hannover) |
 |
11.20
6 |
A phantom for a new easy-to-use benchmark test for
pointer
navigation
B. Kosmecki, G. Nahles, J. Bier (Berlin) |
 |
11.30
7 |
A simple new method for visualizing the accuracy of
navigation
systems
A. Rose, J. Krüger (Berlin) |
 |
11.40
8 |
Optimierung der dreidimensionalen Oberflächenerfassung ver-
schiedener Körperregionen mit Hilfe eines 3-D Laserscanners
L. Kovacs, M. Eder, G. Brockmann, M. Gühring, C. Udosik,
N. A. Papadopulos, E. Biemer (München), H. F. Zeilhofer (Basel) |
 |
11.50
9 |
A methodology for the evaluation of software frameworks in the
domain of computer-assisted surgery
S. Bohn, W. Korb, O. Burgert (Leipzig) |
 |
12.00
10 |
A workflow optimized software platform for multimodal
neurosurgical planning and monitoring
A. Köhn, H. Hahn, J. Klein, J. Breitenborn, U. Siems, T. Böhler,
W. Berghorn (Bremen), E. Simonotto (Gainesville, FL, USA), F. Link,
J. Rexilius (Bremen), R. Lund (Gainesville, FL, USA), H. Jürgens,
H.-O. Peitgen (Bremen) |
 |
12.10
11 |
UML-based modeling of medical applications, workflow in
maxillofacial surgery
M. Toma, A. Busam A., R. Marmulla (Heidelberg) |
 |
12.20
12 |
Rapid prototyping anatomic models for validation of
medical
robot systems
D. Malthan, A. Schäfer (Stuttgart), F. Dammann, E. Schwaderer,
R. Ciuman, J. Rodriguez Jorge, M. M. Maassen (Tübingen) |
 |
12.30–
13.30 |
Mittagspause
mit Besuch der Industrie- und Posterausstellung
im Atrium |
|
| |
13.30–15.30
Robotik I
Vorsitz: H. Iro (Erlangen), T. Lüth (München) |
|
13.30
13 |
Navigation and soft-robotics for accurate placement of biopsy
needles
T. Ortmaier, U. Hagn, L. Le-Tien, C. Ott (Oberpfaffenhofen) |
 |
13.40
14 |
Robot assisted reduction of femur shaft fractures based on
intraoperative 3D imaging
R. Westphal (Braunschweig); T. Gösling, M. Oszwald, J. Bredow,
D. Klepzig (Hannover), S. Winkelbach (Braunschweig), T. Hüfner,
C. Krettek (Hannover), F. Wahl (Braunschweig) |
 |
13.50
15 |
Die erste klinische Anwendung eines navigiert-kontrollierten
Shavers in der Nasennebenhöhlenchirurgie
G. Strauss, M. Hofer (Leipzig), K. Koulechov (München), W. Korb,
O. Burgert, C. Trantakis, A. Dietz, J. Meixensberger (Leipzig), T. Lüth (München) |
 |
14.00
16 |
Robotic guided minimal invasive cochleostomy: first results
M. Leinung (Hannover), R. Heermann (München), O. Majdani (Hannover) |
 |
14.10
17 |
Endpoint planning for a trajectory of a robot-based cochleostomy
– suggestion for radiologic artificial lines
F. B. Knapp (Freiburg), C.-C. Ngan (Karlsruhe), J. Kromeier (Freiburg), J. Raczkowsky (Karlsruhe), J. Schipper, T. Klenzner (Freiburg) |
 |
14.20
18 |
Hexapod-based cochleostomy
C. C. Ngan (Karlsruhe), F. Knapp, J. Schipper, J. Kromeier (Freiburg), J. Raczkowsky, H. Wörn (Karlsruhe), T. Klenzner (Freiburg) |
 |
14.30
19 |
Industrial and technical aspects in the development tasks of a
camera guidance-system for minimally invasive intervention
J. Knapp, M. Sellen (Barbing/Regensburg) |
 |
14.40
20 |
Robot-assisted 3D ultrasound scanning with IR navigation support
P. J. Stolka (Bayreuth), S. H. Tretbar (St. Ingbert), M. Waringo
(Bayreuth), P. Federspil (Heidelberg), D. Henrich (Bayreuth) |
 |
14.50
21 |
Sensor-based force measurement during FESS for robot
assisted surgery
K. Tingelhoff, I. Wagner, K. Eichhorn (Bonn), R. Westphal, F. M. Wahl (Braunschweig),
F. Bootz (Bonn) |
 |
15.00
22 |
Evaluation of an intuitive control system for an interactive robotic system
C. Lenze, M. Brell, A. Hein (Oldenburg) |
 |
15.10
23 |
Prototypic setup of a surgical force feedback instrument for
minimally invasive robotic surgery
B. Kübler, G. Passig, U. Seibold, G. Hirzinger (Oberpfaffenhofen) |
 |
15.20
24 |
Tactile sensors for determination of elastic consistency
differences in brain tissue mimicking phantoms
R. Stroop, R. Kehl, D. Oliva Uribe, T. Hemsel, B. Henning (Paderborn) |
 |
15.30–
16.00 |
Kaffeepause
mit Besuch der Industrie- und Posterausstellung im Atrium |
|
Donnerstag, 12.10.2006,
Operationssaal der Zukunft I
Vorsitz: T. Lenarz (Hannover), J. Meixensberger (Leipzig)
13.30–15.00
Hörsaal S
|
13.30
35 |
Intraoperative three-dimensional visualization for improved
microvascular decompression
P. Hastreiter, L. Tanrikulu, R. Naraghi (Erlangen) |
 |
13.40
36 |
Advanced 2D-3D registration method for transarterial
chemoembolizations
M. Groher, T. F. Jakobs, M. Reiser, N. Navab (München) |
 |
13.50
37 |
The frameless placement of convection-enhanced delivery
catheters using neuronavigation
L. Dörner, N. Warneke, F. Schwartz, H. M. Mehdorn, A. Nabavi (Kiel) |
 |
14.00
38 |
Intrainterventional registration of 3D ultrasound to models of the
vascular system of the liver
D. Zühlke (Bonn), S. Arnold (St. Augustin), G. Grunst, P. Wisskirchen (Bonn) |
 |
14.10
39 |
Registration of 3D rotational angiography to CT/MR angiography
M. Kersten, J. Hoffmann, D. Freudenstein, M. Tatagiba (Tübingen),
Z. Gürvit (Frankfurt), D. Bartz (Tübingen) |
 |
14.20
40 |
Preliminary clinical results with the MRI-compatible guiding
system innomotion
M. Rasmus, S. Dziergwa, T. Haas, P. Madoerin, R. Huegli, D. Bilecen, A. L. Jacob (Basel) |
 |
14.30
41 |
Rapid prototyping for manufacturing of individual stereotaxic
device in diagnostic and functional neurosurgery
D. Winkler, G. Strauß, J. Fischer, A. Richter, J. Meixensberger (Leipzig) |
 |
14.40
42 |
Zielgenaue Infusion – Physiologische Simulation zur Behandlungs-
optimierung
A. Hartlep (Feldkirchen) |
 |